CCNFT - 2921 (BELZONA ELASTOMER GP CONDITIONER), 1200/1153

  • MSDS: CCNFT
  • Manufacturer: BELZONA AMERICA INC
  • Product Name: 2921 (BELZONA ELASTOMER GP CONDITIONER), 1200/1153
  • National Stock Number: 8040-00N027848
Product Identification

Product ID:2921 (BELZONA ELASTOMER GP CONDITIONER), 1200/1153
MSDS Date:02/19/1992
FSC:8040
NIIN:00N027848
MSDS Number: CCNFT

Responsible Party
BELZONA AMERICA INC
2000 NW 88 COURT
MIAMI, FL 33172
US

Emergency Phone: 305-274-6512

Info Phone: 305-594-4994

Preparer: J. PARTINGTON

Cage: 0PX05

Contractor
BELZONA INC.
MIAMI, FL 33172 US

Telephone: 305-594-4994

Cage: 0PX05

Ingredients

CONTACT WITH SKIN & EYES.

RTECS: 9999999ZZ


WORN AND CLEANED THOROUGHLY BEFORE REUSE.

RTECS: 9999999ZZ


DANGEROUS. CHECK ALL CNTNRS FOR LEAKS AT

RTECS: 9999999ZZ


ISOCYANIC ACID, METHYLENEDI-P-PHENYLENE ESTER;

CAS: 101-68-8

RTECS: NQ9350000

Fraction By Weight: 1-5%

OSHA PEL 0.02 PPM, C

ACGIH TLV: 0.005 PPM

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


METHANE, DICHLORO-; (DICHLOROMETHANE) (SARA 313) (CERCLA)

CAS: 75-09-2

RTECS: PA8050000

Fraction By Weight: 60-100%

OSHA PEL 500 PPM

ACGIH TLV: 50 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: CHLOROCARBON MATERIALS HAVE
PRDCED SENSITIZATION OF THE MYOCARDIUM TO EPINEPHRINE IN LAB
ANIMALS & COULD HAVE SIMILAR EFT IN HUMANS. ADRENOMIMETICS (EG,
EPINEPHRINE) MAY BE CONTRA-INDICATED EXC EPT FOR LIFE-SUSTAINING
USES IN HUMANS ACUTELY/CHRONICALLY EXPOSED TO CHLOROCARBONS . SKIN,
EYE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE: IARC MONOGRAPHS
SUPP, VOL 7, PG 194, 1987:GROUP 2B. NTP 7TH ANNUAL REPORT ON
CARCINS, 1994: (SUPDAT)
Effects of Overexposure:HLTH HAZ: & RESP TRACT IRRIT-SYMPS CAN BE
DELAYED UP TO SEVERAL HRS AFTER EXPOS. VAPS ARE NARC & CNS
DEPRESSANT. CAUSES DROW, DIZZ, DRUNKENNESS, NAUS & HIGH CONCS OF
VAP CAN CAUSE CARD ARRYTHMIAS (IRR EGULAR HEARTBEATS),
CARBOXYHEMOGLOBINEMIA & UNCON. CHRONIC: CHEM ASTHMA, SENSIT & DERM.
POSS RISK OF IRREVERSIBLE EFTS.
Medical Cond Aggravated by Exposure:SKIN, EYE AND RESPIRATORY
CONDITIONS.

First Aid

First Aid:INHAL: IF SYMPS ARE EXPERIENCED, MOVE TO FRESH AIR IMMED. IF
RECOVERY IS DELAYED/THERE ARE SIGNS OF DISTRESS OBTAIN MED ATTN
IMMED. EYE: FLUSH W/WATER FOR AT LEAST 15 MIN. SEEK MED ADVICE IF
ANY IRRIT PERSISTS. SKIN: IMMED REMOVE EXCESS W/CLEAN CLOTH & WASH
THORO W/SOAP & WATER. IF IRRIT/INFLAM PERSISTS, SEEK MED ADVICE.
INGEST: IF SWALLOWED, DO NOT INDUCE VOMIT. DANGER OF ASPIR OF VAPS
(SUPDAT)

Fire Fighting

Lower Limits:14%
Upper Limits:22%
Extinguishing Media:WATER FOG (NOT A DIRECT STREAM OF WATER), FOAM,
CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH APPRVD PRESS DEMAND SCBA & FULL
PROT EQUIP . NOT FLAM. IF INVOLED IN FIRE THIS PROD WILL NOT
CONTRIBUTE TO COMBUST MATL. HOWEVER, SPEC (SUPDAT)
Unusual Fire/Explosion Hazard:THERMAL DECOMP PROD MAY INCL HCL &
PHOSGENE . NOT FLAMMABLE, HOWEVER VAPORS CAN FORM EXPLOSIVE MIXTURE
W/AIR. DECOMP & COMBUST PRODS MAY BE HAZARDOUS.

Accidental Release

Spill Release Procedures:ABSORB WITH A DRY INERT MATERIAL (EG SAND).
SWEEP UP, PLACE INTO SUITABLE LABELED CONTAINERS, SEAL AND DISPOSE
OF PROPERLY. FLUSH AREA WITH DILUTE AMMONIUM HYDROXIDE OR
WATER-ALCOHOL MIXTURE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:OVERHEATING MAY CAUSE CNTNRS TO
RUPTURE. UNOPENED CNTNRS SHOULD BE STORED UNDER COOL, DRY CNDTNS.
EMPTY CNTNRS WILL RETAIN RESIDUE & MAY BE (ING 3)
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN THE GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR
UV RADIATION MAY CAUSE THE FORMATION OF HCL AND/OR PHOSGENE .

Exposure Controls

Respiratory Protection:IN CONFINED AREAS OR WHERE GOOD
NATURAL/MECHANICAL VENTILATION IS NOT AVAILABLE, LEADING TO A RISK
OF EXCEEDING THE TLV'S INDICATED, AN APPROPRIATE NIOSH APPROVED
RESPIRATOR SHOULD BE WORN.
Ventilation:WHERE ADEQUATE NATURAL VENTILATION IS NOT AVAILABLE PROVIDE
SUITABLE LOCAL EXHAUST VENTILATION.
Protective Gloves:IMPERMEABLE SUCH AS NEOPRENE OR PVC.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPRVED EYE WASH & DELUGE SHOWER .
WHERE THERE IS RISK OF CONTAM OF FOOTWEAR, SFTY BOOT SHOULD BE (ING
5)
Work Hygienic Practices:WHEN USING, DO NOT EAT/DRINK/SMOKE. REMOVE
CONTAMD CLTHG & LAUNDER BEFORE REUSE. WASH HANDS W/SOAP & WATER
AFTER HNDLG.
Supplemental Safety and Health
FIRE FIGHT PROC: FIRE FIGHTING PROCS MAY BE REQD FOR OTHER MATLS
INVOLVED. EXPLAN OF CARCIN: ANTIC TO BE CARCIN. ANIMAL:LUNG, LIVER,
SALIVARY, MAMMARY GLAND (TUMORS). FIRST AID PROC: IF VOMIT OCCURS.
RINSE MOUTH W/WATER & DRINK PLENTY OF WATER. CALL TAMPA BAY
REGIONAL POIS CTR (1-800-282-3171) & SEEK MED ATTN IMMED.

Chemical Properties

Boiling Pt:B.P. Text:104F,40C
Vapor Pres:355 @ 20C
Vapor Density:HVR/AIR
Spec Gravity:1.27
Solubility in Water:NEGLIGIBLE (<0.1%)
Appearance and Odor:CLEAR LIGHT BROWN LIQUID WITH A SLIGHT ODOR.
Percent Volatiles by Volume:60-100

Stability

Stability Indicator/Materials to Avoid:YES
WATER (CARBON DIOXIDE EVOLVED), STRONG OXIDIZERS, ALCOHOL OR AMINES.
Stability Condition to Avoid:OPEN FLAMES, HOT GLOWING SURFACES AND
ELECTRIC ARCS.
Hazardous Decomposition Products:HCL, PHOSGENE . GASEOUS COMBINATIONS
OF CARBON, CHLORINE, HYDROGEN, NITROGEN & OXYGEN MAY OCCUR AT
ELEVATED TEMPS.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.